forked from sdr/gr-osmosdr
bladeRF: Add XB-200 support
This commit adds support for the bladeRF XB-200 transverter expansion board. To enable the expansion board and to allow the osmocom source or sink to tune down to 0Hz, parameter xb200 has to be set. XB-200 comes with 4 filter banks which can be selected by passing their name as a value of the xb200 parameter. Automatic filter selection will be enabled if no value is given to the xb200 parameter. Example: osmocom_fft -a bladerf,xb200 osmocom_fft -a bladerf,xb200=50M The following values are valid: "custom" : custom band "50M" : 50MHz band "144M" : 144MHz band "222M" : 222MHz band "auto3db" : Select fiterbank based on -3dB filter points "auto" : Select filerbank based on -1dB filter points (default)soapy_support
parent
c65d205d3b
commit
9cb023b00a
|
@ -48,7 +48,13 @@ using namespace boost::assign;
|
|||
boost::mutex bladerf_common::_devs_mutex;
|
||||
std::list<boost::weak_ptr<struct bladerf> > bladerf_common::_devs;
|
||||
|
||||
bladerf_common::bladerf_common() : _conv_buf(NULL), _conv_buf_size(4096) {}
|
||||
bladerf_common::bladerf_common() :
|
||||
_conv_buf(NULL),
|
||||
_conv_buf_size(4096),
|
||||
_xb_200_attached(false)
|
||||
{
|
||||
|
||||
}
|
||||
|
||||
bladerf_common::~bladerf_common()
|
||||
{
|
||||
|
@ -301,10 +307,37 @@ void bladerf_common::init(dict_t &dict, bladerf_module module)
|
|||
"and will have no effect. This parameter should be "
|
||||
"specified on the associated bladeRF source."
|
||||
<< std::endl;
|
||||
|
||||
|
||||
}
|
||||
|
||||
if ( dict.count("xb200") ) {
|
||||
if (bladerf_expansion_attach(_dev.get(), BLADERF_XB_200)) {
|
||||
std::cerr << _pfx << "Could not attach XB-200" << std::endl;
|
||||
} else {
|
||||
_xb_200_attached = true;
|
||||
|
||||
bladerf_xb200_filter filter = BLADERF_XB200_AUTO_1DB;
|
||||
|
||||
if ( dict["xb200"] == "custom" ) {
|
||||
filter = BLADERF_XB200_CUSTOM;
|
||||
} else if ( dict["xb200"] == "50M" ) {
|
||||
filter = BLADERF_XB200_50M;
|
||||
} else if ( dict["xb200"] == "144M" ) {
|
||||
filter = BLADERF_XB200_144M;
|
||||
} else if ( dict["xb200"] == "222M" ) {
|
||||
filter = BLADERF_XB200_222M;
|
||||
} else if ( dict["xb200"] == "auto3db" ) {
|
||||
filter = BLADERF_XB200_AUTO_3DB;
|
||||
} else if ( dict["xb200"] == "auto" ) {
|
||||
filter = BLADERF_XB200_AUTO_1DB;
|
||||
} else {
|
||||
filter = BLADERF_XB200_AUTO_1DB;
|
||||
}
|
||||
|
||||
if (bladerf_xb200_set_filterbank(_dev.get(), module, filter)) {
|
||||
std::cerr << _pfx << "Could not set XB-200 filter" << std::endl;
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
/* Show some info about the device we've opened */
|
||||
std::cerr << _pfx << "Using nuand LLC bladeRF #" << device_number;
|
||||
|
@ -387,7 +420,7 @@ void bladerf_common::init(dict_t &dict, bladerf_module module)
|
|||
osmosdr::freq_range_t bladerf_common::freq_range()
|
||||
{
|
||||
/* assuming the same for RX & TX */
|
||||
return osmosdr::freq_range_t( 300e6, 3.8e9 );
|
||||
return osmosdr::freq_range_t( _xb_200_attached ? 0 : 300e6, 3.8e9 );
|
||||
}
|
||||
|
||||
osmosdr::meta_range_t bladerf_common::sample_rates()
|
||||
|
|
|
@ -82,6 +82,8 @@ protected:
|
|||
|
||||
std::string _pfx;
|
||||
|
||||
bool _xb_200_attached;
|
||||
|
||||
/* BladeRF IQ correction parameters */
|
||||
static const int16_t DCOFF_SCALE = 2048;
|
||||
static const int16_t GAIN_SCALE = 4096;
|
||||
|
|
Loading…